A failing capacitor is one of the most common reasons a fan slows down, a single-phase pump refuses to start, or an AC's outdoor unit hums without running. The good news: it is usually the cheapest part to replace — once you are sure it is the culprit.
Safety first: a capacitor can hold a charge even after the power is switched off. Isolate the supply and discharge the capacitor before handling it — through a suitable resistor, not by shorting the terminals with a screwdriver.
All three point to a weak or failed fan capacitor.
A failed start capacitor stops the motor from starting at all; a weak run capacitor lets it start but run hot and inefficiently. See our submersible pump capacitors, motor start and motor run ranges. If your starter is also tripping, read why a starter keeps tripping.
Most split ACs use a dual capacitor serving both the compressor and the outdoor fan — one part failing can stop both. See AC / dual capacitors.
A washing machine whose drum turns weakly in one direction, or a tube-light fitting with a poor power factor, can also trace back to its capacitor — see washing machine and lighting capacitors.
With the capacitor removed and discharged, check it for:
Any of these means replace it — no testing needed.
A capacitor can look perfect and still have lost much of its capacitance. To test it:
Run capacitors are typically labelled with a tolerance such as ±5%. If your reading is more than about 10% below the rated value, the capacitor is on its way out — replace it before it damages the motor.
Our guide to MPP capacitors and self-healing technology explains what happens inside a capacitor as it ages.
Match these four things to the old capacitor's label:
Look for the ISI / BIS mark and IS 2993 on the label — it means the capacitor has been made and tested to the Indian standard rather than simply copied to look like one.
Not sure which capacitor you need? Send a photo of the old label on WhatsApp and we'll match it for you. You can also browse the full Paramoon capacitor range.